5秒后页面跳转
HEMG49-S120400-7 PDF预览

HEMG49-S120400-7

更新时间: 2022-03-20 10:15:02
品牌 Logo 应用领域
HITRON 医疗输入元件
页数 文件大小 规格书
2页 82K
描述
UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION

HEMG49-S120400-7 数据手册

 浏览型号HEMG49-S120400-7的Datasheet PDF文件第2页 
H HiTRON  
UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION  
EXTERNAL DESKTOP SWITCHING ADAPTER 48-50 WATTS  
GREEN POWER SINGLE OUTPUT HEMG49 SERIES  
FEATURES:  
ACCOMMODATE UNIVERSALAC INPUT  
MEET MEDICAL STANDARDS IEC60601-1  
& ITE STANDARDS IEC60950-1  
EMI MEET EN 55011 & EN55022 /  
FCC CLASS B  
NO LOAD POWER CONSUMPTION <0.3 W  
CE MARKING COMPLIANCE  
SPECIFICATION  
INPUT SPECIFICATION  
OUTPUT SPECIFICATION  
Output Voltage: See Ratings Chart.  
Output Current: See Ratings Chart.  
Output Wattage: Typical 48-50Watts.  
Output Connector & Cord: Optional.  
Line Regulation: Typical 0.1%.  
Input Voltage: Typical 90-264Vac.  
Input Connector: 3 pole AC inlet IEC320-C14(DT7) /  
2 pole AC inlet IEC320-C8(DT8).  
Input Frequency: 47-63Hz.  
Inrush Current: 105A peak at 230Vac.  
Input Current: Typical 0.9A at 115Vac/ 0.57A at 230Vac.  
Dielectric Withstand: Meet IEC60601-1 & IEC60950-1.  
EMI: Meet EN55011 & EN55022 / FCC Class B.  
Hold-up Time: Typical 12mS at 115Vac.  
Typical 70mS at 230Vac.  
Over Temp. Protection: Optional (NTC circuit).  
Earth Leakage Current (Class I): Less than 0.3 mA.  
Touch Leakage Current (Class I & II): Less than 0.1mA.  
No Load Power: Less than 0.3W at 230Vac  
Load Regulation: Typical ±1.5-3.0%.  
Noise & Ripple: 1.0% peak to peak.  
OVP: Built-in by latch circuit.  
Adjustability: Factory set.  
Over Current Protection (OCP):  
Fully protected against output overload and short circuit.  
The PSU will shut down after OCP is activated.  
Consult the factory for OCP setting.  
GENERAL SPECIFICATION  
Efficiency: Typical 87%-88% (various with the output  
voltage)  
Operating Temperature: 0°C to +40°C.  
Storage Temperature: -20 to +85°C.  
Cooling: Free air convection.  
Construction: Impact resistant thermo-plastic  
enclosure case.  
Switching Frequency: Typical 65KHz.  
Circuit Topology: Fixed Frequency Flyback circuit.  
Transient Response: Output voltage returns in less than  
5.5mS following a 50% load change.  
Power Density: 3.14-3.27Watts. / Cubic inch.  
Desktop Format.  
Safety Standard: Meet Medical IEC60601-1 & ITE  
IEC60950-1, Class I for DT7(C14) or Class II for DT8(C8).  
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.  
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (%).  
(3) The exact obtainable load regulation depends upon the output cord selected and load current.  
(4) Due to requests in market and advances in technology, specifications subject to change without notice.  
For the details of safety approval, please consult the factory.  
-7-  
Revised April 15, 2013  

与HEMG49-S120400-7相关器件

型号 品牌 描述 获取价格 数据表
HEMG49-S120400-8 HITRON UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION

获取价格

HEMG49-S150330-7 HITRON UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION

获取价格

HEMG49-S150330-8 HITRON UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION

获取价格

HEMG49-S240210-7 HITRON UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION

获取价格

HEMG49-S240210-8 HITRON UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION

获取价格

HEMG56 HITRON Energy Efficiency Level VI

获取价格