VER : A_1
update : 2015.03.16
DC-DC Brick
BR120 SERIES
100/120 Watts
DESCRIPTION
KEY FEATURES
Input under Voltage Protection
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Remote ON/OFF Control
The BR120 series is a new generation isolated DC-DC converter that uses an
industry standard quarter-brick structure, and features high efficiency and
power density, operates from an input voltage range of 36 V to 75 V,
provides the rated output voltage of 5V / 12V and the maximum output current
of 20A / 10A.
Remote Sense
Output Voltage Trim *
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
Rohs6 Compliant
Size: 2.28 x 1.45 x 0.39 Inches
3-Years Product Warranty
*BR120-12S without this function
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
BR120-5S
100W
BR120-12S
120W
Voltage (V.DC.)
Current (A) (max)
48V (36~75V)
3.4A
Input
4.0A
3W
12V
No-Load Loss (W) (typ.)
Voltage (V.DC.)
2.88W
5V
Regulated Voltage Precision (max.)
Current (A) (max.)
3%
20A
10A
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
0.2%
0.3%
Output
120 mV
200 mV
100% Load 87%
50% Load 85%
20% Load 78%
93.5%
92.5%
87.5%
(Vin = 48 V; TA=25°C (77°F))
Over Power Protection
Hiccup mode
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
Hiccup mode
105~115V (Hiccup mode)
Hiccup mode
6.0~7.5V (Hiccup mode)
Protection
Threshold:100~135°C (typ.) / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Voltage (V.DC.)
1500 VDC (Functional Isolation)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
Environment
MTBF
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
Safety
EMC
Agency Approvals
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
2.28 x 1.45 x 0.39 Inches ( 57.9 x 36.8 x 10.0 mm ) Tolerance 0.5 mm
39 g
Physical
Remote
On/Off Voltage
On/Off Current
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
-0.7~1.2V
3.5~12V
1mA
Other
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319