VER : A_5
update : 2016.04.19
AC-DC Power Module
AUC SERIES
7 Watts
KEY FEATURES
Switching Power Module for PCB Mountable
Fully Encapsulated Plastic Case
Universal Input Range 90-264VAC, 50 / 60 Hz
No-Load Watts < 0.1W
Ultra Compact Size: 1.08” x 1.08” x 0.736” Inches
Isolation Class II
CE, CB, UL Approval
3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AUC-5S
6.3W
AUC-12S
7W
AUC-15S
AUC-24S
Model No.
( Single Output )
Max Output Wattage (W)
Voltage
90-264 VAC or 120-370 VDC, “ N ” to DC “ + “ ; “L ” to DC “ - “
50 / 60 Hz
Frequency (Hz)
Current (Full load)
Inrush Current
180 mA max. (115 VAC) / 110 mA max. (230 VAC)
20 A max. (115 VAC) / 40 A max. (230 VAC)
0.25 mA max. (at <240 VAC).
Input
(Note 4.)
Leakage Current
External Fuse (mandatory)
Voltage (V.DC.)
2 A slow blow type
5V
12V
583
15V
466
24V
292
Voltage Accuracy
±2%
Current (mA) max
Line Regulation (LL-HL) (typ.)
1260
±0.5%
Load Regulation (10-100%) (typ.)
Minimum Load
±1%.
Output
0%
Maximum Capacitive Load
Ripple
3300uF
<100mV (Vp-p)
<150mV (Vp-p)
77%
1000uF
80%
470uF
80%
68uF
<200mV (Vp-p)
<200mV (Vp-p)
80%
Noise
Efficiency (at 230 VAC)
Hold-up Time (at 230 VAC)
Over Power Protection
Short Circuit Protection
Input-Output (V.AC)
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity
30 ms min.
Hiccup technique, auto-recovery
Hiccup mode, indefinite (automatic recovery)
3000V
Protection
Isolation
-40°C…+70°C ( with derating )
-40°C…+85°C
Environment
±0.02%/°C
95% RH
MTBF
>500,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
Case Material
1.08 x 1.08 x 0.736 Inches ( 27.4 x 27.4 x 18.7 mm ) Tolerance 0.5 mm
Plastic resin (flammability to UL 94V-0)
Physical
Weight
26 g
Cooling Method
Free air convection
CE, UL, cUL
Safety
EMC
Agency Approvals
EMI
EN 55022 class B
EN 55024
(Conducted & Radiated Emission)
EMS (Noise Immunity)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-