TRUMPower
200W Compact AC/DC Power Supplies
Features :
Universal AC input / Full range
TS200 Series
Built-in active PFC function
High efficiency up to 90% (typ)
Protections: Short circuit / Overload / Over voltage / Over temperature
PWM control and regulated
High power density 9.78W/inch3
5"x3" compact size
Built-in remote sense function
ZVS technology to reduce power dissipation
Free air convection for 150W and 200W with 20.5 CFM forced air
3 years warranty
SPECIFICATION
TS200-05
PPS-200-5
TS200-12
PPS-200-12
TS200-15
PPS-200-15
TS200-24
PPS-200-24
TS200-27
PPS-200-27
TS200-48
PPS-200-48
P
M
A
O
R
D
T
ELNO.
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
36A
16.6A
13.3A
8.3A
7.4A
4.167A
0 ~ 3.13A
0 ~ 4.167A
150W
CURRENT RANGE (convection) 0 ~ 26A
CURRENT RANGE (20.5CFM FAN) 0 ~ 36A
RATED POWER (convection) 130W
RATED POWER (20.5CFM FAN) 180W
RIPPLE & NOISE (max.) Note.2 100mVp-p
0 ~ 12.5A
0 ~ 16.6A
150W
0 ~ 10A
0 ~ 13.3A
150W
0 ~ 6.25A
0 ~ 8.3A
150W
0 ~ 5.56A
0 ~ 7.4A
150W
199.2W
100mVp-p
10.8 ~ 13.2V
3.0%
199.5W
100mVp-p
13.5 ~ 16.5V
3.0%
199.2W
150mVp-p
21.6 ~ 26.4V
2.0%
199.8W
150mVp-p
24.3 ~ 30V
2.0%
200W
OUTPUT
250mVp-p
43.2 ~ 52.8V
2.0%
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 4.0%
4.5 ~ 5.5V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1200ms, 60ms/230VAC
2500ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
12ms/230VAC/115VAC at full load
90 ~ 264VAC
47 ~ 63Hz
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
PF>0.93/230VAC
86%
PF>0.98/115VAC at full load
89%
89%
89%
89%
90%
INPUT
2.2A/115VAC
1.2A/230VAC
COLD START 70A/230VAC
<2mA / 240VAC
LEAKAGE CURRENT
105 ~ 135% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.6 ~ 7.25V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
31.05 ~ 36.45V
57.6 ~ 67.2V
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 (TSW1) detect on heatsink of power transistor
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +85 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
108.4Khrs min. MIL-HDBK-217F (25
127*76.2*34.6mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.37Kg; 36pcs/14.3Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Heat Sink HS1,HS2 can not be shorted.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
TumblerTechnologies+TRUMPower•SantaClara,CA,USA•408-988-6616•sales@trumpower.com•www.TRUMPower.com