5秒后页面跳转
REX12D PDF预览

REX12D

更新时间: 2022-02-26 10:52:23
品牌 Logo 应用领域
ETAL /
页数 文件大小 规格书
6页 1396K
描述
Control, diagnosis and monitoring via IO link

REX12D 数据手册

 浏览型号REX12D的Datasheet PDF文件第2页浏览型号REX12D的Datasheet PDF文件第3页浏览型号REX12D的Datasheet PDF文件第4页浏览型号REX12D的Datasheet PDF文件第5页浏览型号REX12D的Datasheet PDF文件第6页 
Electronic circuit protector REX12D  
Description  
The requirements regarding modern machinery and equipment are  
constantly growing. System transparency, remote maintenance and  
remote access are getting more and more important in international  
competition. Early notification in the event of any disturbances and  
a fast response to current problems will increase system availability,  
save costs and improve the overall stability of the production process.  
E-T-A provides the ideal solution for machine and panel builders with  
the intelligent protection system comprising the REX12D-T circuit  
protector and the EM12D interface module. The system combines  
the well-proven quality of DC24V overcurrent protection with the  
communication options of the IO link system. It allows complete  
transparency of the DC24V power supply and provides all necessary  
information for a reliable production process in this sector.  
The 12.5 mm wide modules feature push-in technology for wiring  
with press release buttons and allow no-tool time-saving and mainte-  
nance-free wiring. The supply module is designed for DC 24 V and 40  
A and accommodates max. 10 mm² with wire end ferrule as a plus (+)  
supply. On the load output side the circuit protector can be wired  
with 2.5 mm². It is exactly tailored to the needs of machine and panel  
builders. And what is more: no additional accessories are required when  
connecting the individual components electrically and mechanically.  
This helps save time and money!  
Technical data (T  
= +23 °C, U = DC 24 V)  
B
amb  
REX12D-TAx-xxx circuit protectors  
REX12D-TA1-100-DC24V-xA  
REX12D-TA2-100-DC24V-xA/xA  
1-channel  
2-channel  
Operating voltage UB  
DC 24 V (18...30 V)  
Closed-circuit current I0  
REX12D-TA1 1-channel in ON condition:  
REX12D-TA2 2-channel in ON condition:  
typically 7 mA  
typically 10 mA  
Features  
Reverse polarity protection yes  
l
Power failure buffering time up to 10 ms  
Control, diagnosis and monitoring via IO link  
Combination of supply module and electronic circuit protector  
Double channel selective load protection by means of electronic  
l
Current ratings IN  
REX12D-TA1  
fixed ratings:  
8 A, 10 A  
l
REX12D-TA2  
current ratings  
2 A / 2 A, 4 A / 4 A, 6 A / 6 A  
trip curve  
l
No accessories required for connecting the components  
l
Width per channel only 6.25 mm (2-channel)  
Visual status indication  
by LED  
green:  
load circuit connected  
l
lꢀ  
l
l
l
Fixed current ratings from 2 A, 4 A, 6 A, 8 A and 10 A  
Integral fail-safe element, adjusted to current rating  
Switching capacitive loads up to 20,000 µF  
Manual ON/OFF/reset momentary switch  
Connection via push-in terminals including press release buttons  
green/orange  
blinking:  
load current warning limit  
reached 50 % – 100 %  
orange:  
- overload reached, switch-off  
delay depending on the load  
current, active for max. 3 s  
Benefits  
- circuit protector was  
switched off by the  
superordinate control unit,  
LED is permanently orange  
lꢀ Increases machine availability through high transparency and  
remote diagnosis  
lꢀꢀ Saves cost – no further accessories equired  
lꢀꢀ Saves time through innovative and flexible mounting and  
connection technology  
lꢀꢀ Saves space – with a width of only 6.25 mm per channel (2-channel)  
lꢀꢀ Provides flexibility through ease of mounting, disassembly and  
modular design  
red:  
- after disconnection due to  
overload or short circuit  
- after undervoltage release  
of operating voltage in ON  
condition with autoreset  
Approvals and standards  
OFF:  
Device was switched off via  
ON/OFF momentary switch,  
or due to lacking operating  
voltage or faulty initialisation  
of the circuit protector  
Approval  
authority  
Standard  
Rated  
Current  
voltage  
rating range  
UL  
UL  
UL 2367  
DC 24 V  
2 A…10 A  
2 A…10 A  
Load circuit  
UL60947 / cULus508listed DC 24 V  
under preparation  
Load output  
power MOSFET switching output  
(plus switching)  
7
Load current warning limit typically 0.5 - 1.0 x IN (parameterisable)  
(IWLimit  
)
hysteresis  
typically 5 %  
Overload current  
disconnection (IOL  
with trip times (tOL  
typically IOL: IN x 1.05  
typically IOL: IN x 1.35  
typically IOL: IN x 2.00  
typically IOL: IN x 2.50  
tOL: 3s  
tOL: 0.5,5s  
tOL: 0.1s  
tOL: 0.012 s  
tSC: 0.002 s1)  
)
)
short circuit  
typically at short circuit (ISC  
)
trip time (tSC  
)
see time/current characteristic  
1) depending on the power source  
1646  
www.e-t-a.de  
1

与REX12D相关器件

型号 品牌 描述 获取价格 数据表
REX12D-TA1-100-DC24V-10A ETAL Control, diagnosis and monitoring via IO link

获取价格

REX12D-TA1-100-DC24V-8A ETAL Control, diagnosis and monitoring via IO link

获取价格

REX12D-TA2-100-DC24V-2A ETAL Control, diagnosis and monitoring via IO link

获取价格

REX12D-TA2-100-DC24V-4A ETAL Control, diagnosis and monitoring via IO link

获取价格

REX12D-TA2-100-DC24V-6A ETAL Control, diagnosis and monitoring via IO link

获取价格

REX12-T ETAL Combination of supply module and electronic circuit protector

获取价格