H HiTRON
DUAL SELECTABLE AC INPUT AC-DC 19" COMPATIBLE
DOUBLE EUROCARD MULTI-OUTPUT 360 WATTS
SWITCHING MODE POWER SUPPLIES HSU360 SERIES
FEATURES:
ꢀ DUAL INPUT RANGE USER SELECTABLE
ꢀ DOUBLE OR TRIPLE CONVERTER
ARCHITECTURE
ꢀ 19" COMPATIBLE EUROCARD FORMAT
ꢀ MEET THE SAFETY STANDARDS
ꢀ EMI MEET CISPR PUB. 22 & FCC CLASS A
ꢀ CE MARKING COMPLIANCE
ꢀ 6U X 12HP X 160MM DOUBLE EUROCARD
VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 360 Watts for HSU360/HSU360T.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.4%.
Input Voltage: 115Vac/230Vac dual selectable.
Input Connector: DIN 41612 for HSU360T.
IEC320 AC receptacle for HSU360.
Input Frequency: 47-63Hz
Inrush Current: Typ. 65A @230Vac.
Input Current: HSU360 6.5A@115Vac/3.5A@230Vac.
HSU360T 6.2A@115Vac/3.0A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class A.
Power Fail/OK: Option.
Remote (Logic) Inhibit: Available.
Hold-up Time: Typ. 20mS.
Earth leakage: Typ. 0.3mA @230Vac.
Over Temperature Protection (OTP): Option.
Load Regulation: VO1 typ. ±1.0%(Main).
VO2 typ. ±1.0%(Main).
VO3 typ. ±1.0%(Main).
or typ. ±3.0%(PR) for HSU360T.
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1/VO2/VO3 (Latch).
Adjustability: Available at main output VO1,VO2,VO3.
Remote Sense: Installed at main VO1.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 75-80.0%.
Operating Temperature: 0 to +50°C at full load. Derates
linearly to +70°C at half load.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04%/°C.
Cooling: At least 60cfm forced air flow is required
for full load.
Switching Frequency: Typ. 100K Hz.
Circuit Topology: Forward circuit.
HSU360 triple converter.
HSU360T dual converter architecture.
Transient Response: Typ. 3mS following a 25% load change.
Power Density: 2.28 Watts / Cubic Inch for HSU360 & 360T. Construction format: 12HP(TE)x6Ux160mm
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
19” compatible double Eurocard VMEbus standard.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-61-