H HiTRON
UNIVERSAL AC INPUT HARMONIC CORRECTION
AC-DC 19” COMPATIBLE EUROCARD TRIPLE OUTPUT 300 WATTS
SWITCHING MODE POWER SUPPLIES HPU300 SERIES
FEATURES:
ꢀ ACCOMMODATE UNIVERSALAC SOURCES
ꢀ MEET IEC 61000-3-2 HARMONIC CORRECTION
ꢀ DUAL CONVERTER ARCHITECTURE
ꢀ MEET UNIVERSAL SAFETY STANDARDS
ꢀ 19” COMPATIBLE EUROCARD FORMAT
ꢀ EMI MEET EN 55022 & FCC CLASS B
ꢀ CE MARKING COMPLIANCE
ꢀ 6U X 12HP X 160MM FOR STANDARD VMEbus
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.1%.
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz.
Inrush Current: Typ. <30.6A peak @ 230Vac.
Input Current: 3.7A @ 115Vac, 1.85A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet EN 55022 & FCC B.
Load Regulation: Main VO1: Typ. ±3.0%.
Main VO2: Typ. ±3.0%.
Aux. VO3: Typ. ±5.0% (Common Choke).
Power Factor Correction: Meet Harmonic Correction
IEC 61000-3-2. PF typ. 0.97-0.98.
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at two main output VO1 & VO2.
Adjustability: Available at VO1 & VO2 rails.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Power Indicator: Green LED.
Power OK Signal: Installed.
Logic Inhibit: Installed.
Hold-up Time: 46mS @ 115Vac & 230Vac.
Earth Leakage: Less than 0.60mA @ 230Vac.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 76 - 78%.
Operating Temperature: 0 to +50°C full load & +50 to
+70°C by derating 2%/°C.
Storage Temperature: -25°C to +85°C.
Temperature Coefficient: Typ. 0.03% / °C.
Cooling: Forced air flow is recommended for Ta>+50°C
full load operation.
Switching Frequency: Fixed frequency 93K Hz.
Circuit Topology: Dual converter architecture.
Fixed Frequency Forward circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
Power Density: 2.16 Watt / Cubic Inch.
Construction format: 6Ux12HP(TE)x160mm VMEbus
standard Eurocard format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-59-