Electronic Circuit Protector ESX10  
Description  
Electronic circuit protector type ESX10 is designed to ensure selective  
disconnection of DC 24 V load systems.  
DC 24 V power supplies, which are widely used in industry today, will  
shut down the output in the event of an overload with the result that  
one faulty load in the system can lead to complete disconnection of  
all loads. As well as an unidentified failure this also means stoppage  
of the whole system.  
Through selective disconnection the ESX10 responds much faster  
to overload or short circuit conditions than the switch-mode power  
supply. This is achieved by active current limitation. The ESX10 limits  
the highest possible current to values between 1.3 to 1.8 times the  
selected rated current of the circuit protector. Thus it is possible to  
switch on capacitive loads of up to 75,000 µF lamp loads, but they  
are disconnected only in the event of an overload or short circuit.  
ESX10  
(T  
= 25 °C, operating voltage U = DC 24 V)  
S
Technical data  
ambient  
For optimal alignment with the characteristics of the application the  
current rating of the ESX10 can be selected in fixed values from  
0.5 A...12 A. Failure and status indication are provided by a multicolour  
LED and an integral short-circuit-proof status output or a potential-free  
signal contact.  
Operating data  
Operating voltage US  
Current rating IN  
DC 24 V (18...32 V)  
fixed current ratings: 0.5 A, 1 A, 2 A, 3 A,  
4 A, 6 A, 8 A, 10 A, 12 A  
The ESX10, with a width of only 12.5 mm, can be plugged into the  
E-T-A power distribution socket Module 17plus ensuring ease of  
installation and saving space in control cabinets.  
Closed current I0  
ON condition: typically 20...30 mA  
depending on signal output  
l
Status indication  
by means of  
multicolour LED:  
GREEN:  
unit is ON, power-MOSFET  
is switched on  
- status output SF ON, supplies +DC 24 V  
ORANGE:  
in the event of overload or short circuit  
until electronic disconnection  
RED:  
Upon detection of overload or short circuit in the load circuit, the  
MOSFET of the load output will be blocked to interrupt the  
current flow. The MOSFET and the load circuit may be re-activated  
via the remote electronic reset input or manually by means of the  
ON/OFF button. When starting up the system, the load circuit may  
also be manually disconnected.  
US patent number: US 6,490,141 B2  
- unit electronically disconnected  
- load circuit/Power-MOSFET OFF  
OFF:  
4
- manually switched off (S1 = OFF)  
or device is dead  
Features  
- undervoltage (US < 8 V)  
- after switch-on till the end of the  
l
Selective load protection, electronic trip characteristics.  
Active current limitation for safe connection of capacitive loads  
up to 75,000 µF and on overload/short circuit.  
Current ratings 0.5 A...12 A.  
Reliable overload disconnection with 1.1 x IN plus, even with long  
load lines or small cable cross sections (see table 3).  
Manual ON/OFF button (S1).  
Clear status and failure indication through LED, status output SF  
or Si contact F.  
Electronic reset input RE (option).  
Integral fail-safe element.  
Width per unit only 12.5 mm.  
Plug-in mounting utilising power distribution system Module 17plus  
or SVSxx optionally (see product group Power distribution systems)  
Additional versions with ATEX approval available.  
l
delay period  
status output SF (option)  
potential-free signal contact F (option)  
ON/OFF/ condition of switch S1  
l
l
l
l
l
Load circuit  
l
Load output  
Power-MOSFET switching output  
(high side switch)  
l
Overload disconnection  
Short-circuit current IK  
Trip time  
typically 1.1 x IN (1.05...1.35 x IN)  
active current limitation (see table 1)  
see time/current characteristics  
l
l
l
l
for electronic disconnection typically 3 s at ILoad > 1.1 x IN  
typically 3 s...100 ms at ILoad > 1.8 x IN  
(or 1.5 x IN/1.3 x IN)  
l
Temperature disconnection internal temperature monitoring with  
electronic disconnection  
Marking:  
ESX10-...-E  
II 3G Ex nA IIB T4 Gc X  
Please observe separate operating instructions:  
Low voltage monitoring  
load output  
with hysteresis, no reset necessary  
load “OFF” at US < 8 V  
Starting delay tstart  
typically 0.5 sec after every switch-on  
and after applying US  
Disconnection of load circuit electronic disconnection  
Free-wheeling circuit  
external free-wheeling diode  
recommended with inductive load  
Several load outputs must not be connected in parallel  
1642  
www.e-t-a.de  
1

与ESX10相关器件

型号 品牌 描述 获取价格 数据表
ESX10-100-DC24V-10AE ETAL Selective load protection, electronic trip characteristics

获取价格

ESX10-100-DC24V-12AE ETAL Selective load protection, electronic trip characteristics

获取价格

ESX10-100-DC24V-1AE ETAL Selective load protection, electronic trip characteristics

获取价格

ESX10-100-DC24V-2AE ETAL Selective load protection, electronic trip characteristics

获取价格

ESX10-100-DC24V-3AE ETAL Selective load protection, electronic trip characteristics

获取价格

ESX10-100-DC24V-4AE ETAL Selective load protection, electronic trip characteristics

获取价格