描述
Selective load protection with physical isolation in the event of a fault

ESS20-0 数据手册

 浏览型号ESS20-0的Datasheet PDF文件第2页浏览型号ESS20-0的Datasheet PDF文件第3页浏览型号ESS20-0的Datasheet PDF文件第4页浏览型号ESS20-0的Datasheet PDF文件第5页浏览型号ESS20-0的Datasheet PDF文件第6页 
Electronic Circuit Breaker ESS20-0...  
Description  
Electronic circuit breaker type ESS20-0.. is designed to ensure  
selective disconnection of individual loads in systems which are  
powered by a DC 24 V switch-mode power supply.  
DC 24 V power supplies, which are widely used in industry today, will  
shut down the output in the event of an overload with the result that  
one faulty load in the system can lead to complete disconnection of  
all loads. As well as an unidentified failure this also means stoppage  
of the whole system.  
Through selective disconnection the ESS20-0.. responds much  
faster to overload or short circuit conditions than the switch-mode  
power supply. This is achieved by a combination of active current  
limitation and well-proven circuit breaker technology including  
physical isolation. The ESS20-0.. limits the highest possible current  
to 1.8 or 1.5 times the selected rated current of the circuit breaker.  
Thus it is possible to switch on capacitive loads of up to 75,000 µF  
lamp loads, but they are disconnected only in the event of an overload  
or short circuit.  
ESS20-0..  
(T  
= 25 °C, operating voltage U = DC 24 V)  
Technical data  
ambient  
S
Operating data  
For optimal adjustment to the application conditions the current rating  
of the ESS20-0.. can be selected in fixed values from 0.5 A...10 A and  
in adjustable variants 1 A/2 A or 3 A/6 A. Failure and status indication  
are provided by a bicolour LED and an integral signal contact.  
Operating voltage US  
Current rating IN  
DC 24 V (18...32 V)  
fixed current ratings: 0.5 A, 1 A, 2 A, 3 A,  
4 A, 6 A, 8 A, 10 A  
switchable: 1 A/2 A or 3 A/6 A  
Power consumption  
Trip current (bimetal)  
typically 13 mA  
The ESS20-0.. features a width of only 12.5 mm and can be plugged  
into the E-T-A power distribution socket Module 17plus and SVSxx  
(for ESS20-003) ensuring ease of installation and saving space in  
control cabinets.  
typically 0.3 A  
(only in the event of a failure, before physical isolation)  
Status indication  
by means of  
Bicolour LED:  
Green: unit is ON, power-MOSFET is  
switched on  
Orange: in the event of overload or  
short circuit until physical isolation  
LED not lighted: push button in OFF  
position  
US patent number: US 6,490,141 B2  
Features  
potential-free signal contact (change-  
over contact)  
OFF-position of push button  
l
Selective load protection with physical isolation in the event of a fault.  
All types of loads can be connected (small DC motors etc. on  
request).  
Active current limitation (1.8 or 1.5 times rated current IN = 8 A or  
10 A) for safe connection of capacitive loads up to 75,000 µF and  
on overload/short circuit.  
Electronic trip characteristic.  
Reliable overload disconnection with 1.1 x IN plus, even with long  
l
4
Reverse polarity  
protection of US  
internal bimetal (fail-safe element) trips,  
push button moves into OFF position  
l
Load circuit  
Load output  
Power-MOSFET switching output  
(high side switch)  
l
l
Max. data of load  
load lines or small cable cross sections (see table 2).  
Selectable current ratings (fixed values 0.5 A...10 A or two steps:  
1 A/2 A or 3 A/6 A).  
with side-by-side mounting see table 1  
l
Voltage drop at IN  
see table 1  
l
l
l
l
Overload disconnection  
Short-circuit current IK  
typically 1.1 x IN (1.05...1.35 x IN)  
Manual ON/OFF button (push-push actuation).  
Clear status and failure indication.  
Width per unit only 12.5 mm.  
Plug-in mounting utilising power distribution system Module 17plus  
or SVSxx (for ESS20-003), see product group 7.  
typically 1.8 x IN / active current  
limitation  
Trip time  
for physical isolation  
see time/current characteristics  
typically 5 sec at Iload > 1.1 x IN  
for electronic disconnection typically 5 sec...100 ms at Iload > 1.8 x IN  
or 1.5 x IN  
Approvals  
Temperature disconnection internal temperature monitoring with  
physical isolation  
Authority  
Norm  
Voltage ratings  
Current ratings  
Low voltage monitoring  
load output  
OFF at US < 7 V  
ON at US >16 V  
VDE  
EN  
60934  
DC 32 V  
0.5 A…10 A  
Starting delay tstart  
typically 0.3 sec after every switch-on  
and after applying US  
UL  
UL 1077 DC 28 V  
0.5 A…10 A  
Disconnection of load circuit single pole (switch contact)  
- by push-push actuation of the blue  
push button  
Notes  
- upon electronic fault disconnection  
(overload, short circuit)  
- with reverse polarity  
l
The user should ensure that the cable cross sections of the relevant  
load circuit are suitable for the current rating of the ESS20 used.  
Automatic start-up of machinery after shut down must be prevented  
(Machinery Directive 98/37/EG and EN 60204-1). In the event of  
a short circuit or overload the load circuit will be disconnected  
electronically by the ESS20.  
l
Free-wheeling circuit  
external free-wheeling diode  
recommended with inductive load  
Several load outputs must not be connected in parallel.  
1646  
www.e-t-a.de  
1

与ESS20-0相关器件

型号 品牌 描述 获取价格 数据表
ESS20-001-DC24V-0.5A ETAL Selective load protection with physical isolation in the event of a fault

获取价格

ESS20-001-DC24V-10A ETAL Selective load protection with physical isolation in the event of a fault

获取价格

ESS20-001-DC24V-1A ETAL Selective load protection with physical isolation in the event of a fault

获取价格

ESS20-001-DC24V-2A ETAL Selective load protection with physical isolation in the event of a fault

获取价格

ESS20-001-DC24V-3A ETAL Selective load protection with physical isolation in the event of a fault

获取价格

ESS20-001-DC24V-4A ETAL Selective load protection with physical isolation in the event of a fault

获取价格