Battery Isolation Switch E-1073-437
Description
Single pole circuit breaker type 437 featuring an additional electronic
function module which limits the duration of the supply to the remote
disconnect and re-connect coils, avoiding damage in the event
of unusual operating circumstances. Available with undervoltage
monitoring option to protect batteries from the effects of deep
discharge, status output for undervoltage, auto reset feature.
Typical applications
Battery and cable protection for all types of vehicle (including electric),
battery powered systems.
E-1073-437
Ordering information
Type No.
Technical data of circuit breaker
E-1073 control unit for type 437 with remote control
Voltage rating
0 DC 12 V
1 DC 24 V
see type 437
2
Control mode
Technical data – Electronic module
1
ON/OFF control input
00 without additional function
02 with undervoltage protection and status output
ON and OFF buttons
33 with control current supply and ON/OFF test input
Circuit Breaker
Voltage rating
DC 24 V
2
Voltage rating range
ON
18 - 32 V
OFF 16 - 32 V
Correct switching performance is not
guaranteed if the voltage falls below the
minimum value.
437
single pole circuit breaker (double pole upon request)
Enclosure design (optional)
blank without enclosure
Temperature range
electronic control unit -40...+80 °C (-40...+176 °F)
B3
moulded housing
Terminal design
Operating current
ON approx. 15 A
OFF approx. 20 A
K60
straight flat screw terminal
(for use without housing)
screw terminal, angled 90°
(for use with B3 or B35)
K12
Excitation time
ON typically 100 ms
OFF typically 20 ms
Mounting
Switching frequency
Power consumption
of electronic control unit (when switched off or button operated)
0.1 Hz max.
5 mounting brackets for
surface mounting
Characteristic curve
06 fast trip
typically < 1 mA
Control inputs
E-1073-.1..:
»E/A« (ON/OFF), »U-AUS«
(undervoltage protection OFF), »A-W« (auto reset)
E-1073-.2..:
»T-EIN« (button ON), »T-AUS« (button OFF)
max. 32 V
> 8 V
< 3 V
07 delayed trip
Auxiliary contacts
Si01 one N/C and two N/O
Remote ON and OFF
operation
FC12 DC12V, remote ON/OFF
FC24 DC24V, remote ON/OFF
Suffix
voltage
ON (high)
OFF (low)
power consumption
DC 24 V: typically 5 mA
173027 standard
Current ratings
EMC
according to DIN 40839/ISO 7637
Reverse polarity
protection
If polarized incorrectly, the
circuit breaker will trip after a few seconds.
80 A, 100 A, 120 A,
160A, 180 A, 200 A,
240 A
Undervoltage protection
switching thresholds
hysteresis
optional with E-1073-.1..
DC 24 V: 22.8 V 0.2 V
typically 0.5 V
E-1073-1
1
02 - 437-B3 -K60-5 - 06 -Si01-FC12 - 173027 - 240 A
trip time
typically 40 sec
ordering example
Undervoltage status output »UST«, optional with E-1073-.1..
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
transistor output
current load
minus switching
corresponding to 2 W lamp load, short-
circuit proof
Control current supply »+US2«, with E-1073-.2.. for T-EIN/T-AUS
May be connected to 20 control inputs.
Noise-voltage proof, short-circuit proof
Terminals
control terminals
blade terminals 6.3x0.8 mm
Mass
approx. 2,000 g without enclosure
1646
www.e-t-a.de
1