JFW Industries, Inc.
Phone: 317-887-1340
sales@jfwindustries.com
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50MS-304
SOLID STATE MATRIX SWITCH
Frequency Range
Configuration
2-6 GHz
6 x 6 Non-Blocking Matrix
(See block diagram 092-7408)
(Unused input ports are self-terminating)
(Unused output ports are self-terminating)
(all ports are bi-directional)
(the ADMIN password is located on rear panel)
Startup/Default States
(configurable)
All ports off at startup (see MATRIX command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
Enclosure Type
Impedance
VSWR
19 inch rack mount @ 5RU high
50 Ohms nominal
1.5:1 typical
1.7:1 maximum
Insertion Loss
Isolation
16.5 dB nominal @ 2GHz
18.5 dB nominal @ 6GHz
Input to Input - 70 dB minimum
Input to Output - 70 dB minimum
Output to Output - 18 dB minimum
(If connected to same Input)
Output to Output - 70 dB minimum
(If connected to different Inputs)
RF Input Power
Switching Speed
+20 dBm maximum
1 microsecond
(After command is received and processed)
(3 millisecond typical processing time)
Manual Control
Remote Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED--
Page 1 of 2
JFW FORM E-7-F REV F