5秒后页面跳转
4930-01 PDF预览

4930-01

更新时间: 2022-12-29 21:23:55
品牌 Logo 应用领域
ETAL /
页数 文件大小 规格书
4页 202K
描述
Aircraft electrical systems and equipment, and other high performance applications

4930-01 数据手册

 浏览型号4930-01的Datasheet PDF文件第2页浏览型号4930-01的Datasheet PDF文件第3页浏览型号4930-01的Datasheet PDF文件第4页 
Remote Control Circuit Breaker 4930 (RCCB)  
Description  
Single pole remote control circuit breaker (RCCB), temperature  
compensated, either with or without auxiliary contacts, and featuring  
a bimetal actuator which trips the circuit breaker mechanism within  
a specified time under overcurrent conditions. The switching contact  
latching system is operated by a bi-stable linear motor controlled by  
electronic circuitry incorporated within the device. Remote control  
is achieved through the use of a conventional single pole manually  
operated aircraft style thermal circuit breaker type 4120-0,5 A which  
connects the control input of the RCCB to ground.  
With the control circuit breaker (ICU) in the ON position, the RCCB will  
switch on. When the control circuit breaker is switched off, the RCCB  
will change to the OFF condition. If power is applied to a previously  
de-energised RCCB, the device will adopt the same switching status  
as the control circuit breaker.  
If the RCCB trips thermally in the event of a load circuit fault, the  
electronic circuitry will also cause the control circuit breaker to trip,  
thereby providing a visual indication through the position of the circuit  
breaker actuator.  
1
4930 (RCCB)  
(T = 25 °C, U = DC 28 V or AC 115V/400 Hz)  
Technical data  
A
e
Approved to MIL-PRF-83383.  
Operating data LINE  
(see also MIL-PRF-83383)  
Voltage ratings Ue  
AC 115 V 400 Hz (AC 104...126 V);  
(operating voltage range) DC 28 V (DC 18...36 V)  
Typical applications  
Current rating range IN  
Bias current  
5...100 A (see ordering information)  
Aircraft electrical systems and equipment, and other high performance  
applications.  
typically 2.5 mA at DC 28 V  
typically 25 mA at AC 115 V  
Switching current/  
switching period for  
internal linear motor  
Ordering information  
typically 3.4 A / 28 ms at DC  
typically 2.8 A / 17 ms at AC  
Type No.  
Optical indication ON/OFF status indicator (near terminal A1)  
4930 single pole remote control circuit breaker (RCCB)  
Variation  
Load circuit LOAD  
Current rating range IN  
Interrupting capacity  
5...100 A (see ordering information)  
01 standard, with auxiliary contacts  
02 with modified terminal barrier and auxiliary contacts  
03 standard, without auxiliary contacts  
04 with modified terminal barrier but without auxiliary contacts  
Current ratings  
DC 28 V: 6,000 A  
AC 115 V 400 Hz: 3,600 A  
Voltage drop at IN  
see table 1  
(standard current ratings and  
typical voltage drop values)  
5...100 A  
Overload disconnection  
see table 2  
(typical time/current characteristics)  
4930 - 01 - 5 A ordering example  
Trip limits  
see table 2  
IN/A  
E-T-A  
part number  
MIL  
part number  
E-T-A  
part number  
MIL  
part number  
Control circuit ICU  
ICU  
Indicator/Control Unit  
thermal circuit breaker 0.5 A  
e.g. 4120-G111-K1M1-A1S0ZN-0.5A  
5
4930-01-5A  
M83383/02-01 4930-03-5A  
M83383/02-02 4930-03-7.5A  
M83383/02-03 4930-03-10A  
M83383/02-04 4930-03-15A  
M83383/02-05 4930-03-20A  
M83383/02-06 4930-03-25A  
M83383/02-07 4930-03-35A  
M83383/02-08 4930-03-40A  
M83383/02-09 4930-03-50A  
M83383/02-10 4930-03-60A  
M83383/02-11 4930-03-75A  
M83383/02-12 4930-03-80A  
M83383/01-01  
M83383/01-02  
M83383/01-03  
M83383/01-04  
M83383/01-05  
M83383/01-06  
M83383/01-07  
M83383/01-08  
M83383/01-09  
M83383/01-10  
M83383/01-11  
M83383/01-12  
7.5  
10  
15  
20  
25  
35  
40  
50  
60  
75  
80  
100  
4930-01-7.5A  
4930-01-10A  
4930-01-15A  
4930-01-20A  
4930-01-25A  
4930-01-35A  
4930-01-40A  
4930-01-50A  
4930-01-60A  
4930-01-75A  
4930-01-80A  
Trigger current for ICU  
(“TRIP FREE“-mode) /  
duration  
approx. 3.2 A / 5 s max  
Control voltage UICU  
RCCB “OFF”  
(ICU open)  
Limits:  
UICU > 2 V (25 °C)  
(> 1.5 V between -54...+71 °C /  
-65...+160 °F)  
UICU < 0.6 V (25 °C)  
(< 0.2 V between -54...+71 °C /  
-65...+160 °F)  
RCCB “ON”  
(ICU closed)  
Control current IICU  
typically 0.4 mA  
Additional control units  
one relay contact or one ON/OFF switch  
is applicable (see application note ICU)  
ON/OFF-cycling time  
(e. g. additional relay  
contact in ICU circuit)  
4930-01-100A M83383/02-13 4930-03-100A M83383/01-13  
ON > 80 ms / OFF > 80 ms  
Signal output AUX  
Approvals  
Auxiliary contacts  
change over contacts  
S1 - S2 is open, when RCCB main  
contact is open  
Authority Standard  
Voltage ratings  
Current  
ratings  
Voltage ratings  
Current ratings  
DC 28 V, AC 115 V (400 Hz)  
resistive load: 3 A  
inductive load 1.5 A  
lamp load: 0.5 A  
DSCC  
MIL-PRF-83383 AC 115 V, 400 Hz  
DC 28 V  
5 A…100 A  
5 A…100 A  
1646  
www.e-t-a.de  
1

与4930-01相关器件

型号 品牌 描述 获取价格 数据表
4930-01-100A ETAL Aircraft electrical systems and equipment, and other high performance applications

获取价格

4930-01-10A ETAL Aircraft electrical systems and equipment, and other high performance applications

获取价格

4930-01-20A ETAL Aircraft electrical systems and equipment, and other high performance applications

获取价格

4930-01-40A ETAL Aircraft electrical systems and equipment, and other high performance applications

获取价格

4930-01-50A ETAL Aircraft electrical systems and equipment, and other high performance applications

获取价格

4930-01-5A ETAL Aircraft electrical systems and equipment, and other high performance applications

获取价格