5秒后页面跳转
3120-F PDF预览

3120-F

更新时间: 2022-12-29 17:45:41
品牌 Logo 应用领域
ETAL /
页数 文件大小 规格书
16页 1728K
描述
Medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, offices machines, audio equipment, machine tools

3120-F 数据手册

 浏览型号3120-F的Datasheet PDF文件第2页浏览型号3120-F的Datasheet PDF文件第3页浏览型号3120-F的Datasheet PDF文件第4页浏览型号3120-F的Datasheet PDF文件第5页浏览型号3120-F的Datasheet PDF文件第6页浏览型号3120-F的Datasheet PDF文件第7页 
Thermal Circuit Breaker 3120-F...  
Description  
The 3120 circuit breaker/switch combination is an ON/OFF switch  
with integral overcurrent protection (S-type TO CBE to EN/IEC  
60934). The trip element is a bimetal. Type 3120 is ideally suited for  
overload protection of motors, pumps, transformers and cables.  
Product characteristics:  
l rocker or push button actuation  
l single pole and double pole versions  
l reliable switching behaviour (positively trip-free)  
l convenient snap-in mounting  
l international approvals  
1
Options and add-on modules:  
l illumination  
l water splash protection  
l auxiliary contacts  
l under voltage trip  
l remote trip  
Technical data  
l magnetic trip (see thermal-magnetic circuit breakers)  
l push-in terminals  
For details please see Technical information  
l appliance inlet module  
Rated voltage  
AC 240 V, DC 50 V  
Current rating range  
0.1...20 A  
(up to 30A upon request for single pole  
units)  
Typical applications  
Typical life 1-pole  
Medical and laboratory equipment, apparatus and machine  
construction, professional tools, household and garden appliances,  
offices machines, audio equipment, machine tools  
AC 240 V:  
DC 50 V:  
0.1...20 A 30,000 operations at 1 x IN, inductive  
0.1...4 A 30,000 operations at 1 x IN, inductive  
4.5...16 A 30,000 operations at 1 x IN, resistive  
0.1...20 A 30,000 operations at 1 x IN, inductive  
DC 28 V:  
Typical life 2-pole  
Current ratings and internal resistance values  
AC 240 V:  
DC 50 V:  
0.1...16 A 50,000 operations at 1 x IN, inductive  
17...20 A 30,000 operations at 1 x IN, inductive  
0.1...16 A 50,000 operations at 1 x IN, inductive  
17...20 A 50,000 operations at 1 x IN, inductive  
Current rating Internal  
Current rating Internal  
(A)  
resistance  
(A)  
resistance  
per pole (Ω)  
per pole (Ω)  
0.0435  
0.0435  
0.0325  
0.0215  
0.0165  
0.0165  
< 0.02  
< 0.02  
< 0.02  
< 0.02  
< 0.02  
< 0.02  
< 0.02  
Ambient temperature  
-30 … 60 °C  
0.1  
0.2  
0.3  
0.4  
0.5  
0.6  
0.8  
1
94  
4
Insulation coordination  
(IEC 60664)  
2.5 kV /2 reinforced insulation at  
operating area  
24  
4.5  
5
Dielectric strength  
12  
Operating area  
pole to pole (2-pole)  
test voltage AC 3,000 V  
test voltage AC 1,500 V  
5.30  
6
4.20  
7
Insulation resistance  
> 100 MΩ (DC 500 V)  
2.90  
8
Interrupting capacity Icn 0.1...2 A  
2.5...20 A  
10 x IN  
1-pole 150 A  
2-pole 250 A  
1.50  
10  
12  
14  
15  
16  
18  
20  
0.9  
Interrupting capacity (UL 1077)  
IN  
1.2  
1.5  
2
0.80  
UN  
Inc  
0.45  
1-pole, 2- pole  
1-pole, 2- pole  
0.1...20 A  
0.1...20 A  
AC 250 V  
DC 50 V  
5000 A, C, 1  
1000 A, C, 1  
0.27  
2.5  
3
0.0785  
0.0595  
0.0565  
Degree of protection  
(IEC 60529)  
operating area IP40  
terminal area IP00  
with water splash cover IP54 or IP66  
3.5  
Vibration  
8 g (57-500 Hz), 0.61 mm (10-57 Hz)  
test to IEC 60068-2-6, test Fc  
10 frequency cycles/axis  
Current consumption of illumination  
Shock  
30 g (11 ms)  
test to IEC 60068-2-27, test Ea  
Operating voltage  
Current consumption  
Corrosion  
Humidity  
96 hours at 5 % salt mist,  
test to IEC 60068-2-11, test Ka  
Y
R
G
DC 12 V  
DC 24 V  
DC 48 V  
AC 115 V  
AC 230 V  
5.2 mA  
4.5 mA  
4.5 mA  
2.8 mA  
2.2 mA  
2 mA  
2.2 mA  
2 mA  
1.1 mA  
0.9 mA  
1.4 mA  
1.6 mA  
1.6 mA  
1 mA  
240 hrs in 95 % RH  
test to IEC 60068-2-78,  
test Cab  
Mass  
approx. 33 g (2-pole)  
approx. 27 g (1-pole)  
approx. 42 g (2-pole with PT terminals)  
0.9 mA  
1616  
www.e-t-a.de  
1

与3120-F相关器件

型号 品牌 描述 获取价格 数据表
3120-F301R-G7Q1 ETAL Medical and laboratory equipment, apparatus and machine construction, professional tools,

获取价格

3120-F301R-G7T1 ETAL Medical and laboratory equipment, apparatus and machine construction, professional tools,

获取价格

3120-F301R-H7Q1 ETAL Medical and laboratory equipment, apparatus and machine construction, professional tools,

获取价格

3120-F301R-H7T1 ETAL Medical and laboratory equipment, apparatus and machine construction, professional tools,

获取价格

3120-F301R-N7Q1 ETAL Medical and laboratory equipment, apparatus and machine construction, professional tools,

获取价格

3120-F301R-N7T1 ETAL Medical and laboratory equipment, apparatus and machine construction, professional tools,

获取价格